MDK-MT3 Mag Drive Pump

March Pumpís MDK-MT3 centrifugal sealless magnetic drive pumps ideal for oem applications.
Unit System 60Hz 50Hz
Max Flow 8 GPM 30 LPM
Max Head 16 FT 3.5 M
Power .04 HP .029 KW
Electrical 115V 50/60HZ or 230V 50/60HZ

Type Centrifugal Mag Drive
Inlet 1/2"MPT
Outlet 1/2"MPT
Wet End Carbon filled Kynar (Front and Rear Housing, Impeller), Ceramic (Shaft, Thrust Washer), Viton (O-Ring)

Request Additional Product Info

icon March MTK-MT3 Curve

icon MDK-MT3 Pump Manual

Options:

O-Ring: Viton, Teflon, or Ethylene Propylene

The front housing, rear housing, and impeller are available in Polypropylene. 

Reference Information

icon Dimensional Drawing MDK-MT3 115V

icon Dimensional Drawing MDK-MT3 115V DWG (109 KB)

icon Dimensional Drawing MDK-MT3 230V

icon Dimensional Drawing MDK-MT3 230V DWG (109 KB)

March Pump's industrial MDK-MT3 is an American seal-less centrifugal magnetic drive pump ideal for applications such as chemical recirculation and chemical transfer. It is capable of generating a maximum flow of 8 gallons per minute at 1 foot, and its maximum head is 16 Feet (or around 7PSI). The standard wet end (the materials that come into contact with the solution) is composed of carbon filled Kynar (PVDF), Viton, and Ceramic. The inlet connection is 0.5 inch male pipe thread, and the outlet is 0.5 inch male pipe thread. The standard motor is a 1 Phase 115V or 230V 0.04 Horsepower fan cooled motor, which can be run on either 50 or 60 hertz (there are performance differences between the hertz options).  The maximum internal pressure the pump can tolerate is 75PSI, and the maximum liquid temperature is 200 Fahrenheit or 93 Celsius. The March MDK-MT3 centrifugal magnetic drive pump is capable of handling mildly or highly corrosive chemicals, acids, and solvents. To determine if the March MDK-MT3 is suitable for your application, please contact March Pump. 

Perfect for Applications Including 

Applications for the MDK-MT3 Magnetic Drive Pump include etching equipment, photographic processing equipment, ice flakers, plate processors , and marine air conditioning.

Great for Chemicals Including

The MDK-MT3 has pumped Acetic Acid, Citric Acid, Ethylene Glycol, Formaldehyde, Hydrochloric Acid (Muriatic), Hydrofluoric Acid, Hydrogen Peroxide, Nitric Acid, Phosphoric Acid, Potassium Chloride, Sodium Chloride, Sodium Hypochlorite, Sulfuric Acid, Fresh Water, Salt Water, DI Water, and many more chemicals.  The MDK-MT3 may have been modified to handle these chemicals.  Please contact March Pump to review your application before using the MDK-MT3 for any of the above listed chemicals. 
Chemical Resistance Chart      

Warranty

March Pumps are warranted to the original purchaser thereof to be free of defects in workmanship and materials under normal use for a period of twelve (12) months from the date of manufacture.  This warranty will be extended to (12) months from the date of original installation if the warranty card is completely filled in and returned to March or register online at www.marchpump.com/warranty-registraton   

This warranty covers only units properly installed and maintained in accordance with March instructions.  Any March pump which the purchaser considers to be defective must be returned to the source where it was purchased.  If the pump is found by March to be defective in workmanship or materials under normal use within the warranty period March, at its option, will either replace or repair the pump.  This warranty does not cover any costs associated with the installation or removal of the pump.  If the pump was damaged in transit, you should file a claim with the carrier. 

Before using the pump, the purchaser or installer should determine the suitability of the pump for its intended use.  Purchaser assumes all risk and liability whatsoever in connection with such use or installation.   

MARCH'S SOLE LIABILITY AND THE SOLE REMEDY FOR ANY BREACH OF WARRANTY SHALL BE AS SET FORTH ABOVE.  THE WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES OF MARCH.  WHETHER WRITTEN, ORAL OR IMPLIED, AND MARCH HEREBY DISCLAIMS ANY OTHER REPRESENTATION OR WARRANTY EITHER EXPRESSED OR IMPLIED AS TO ANY MATTER WHATSOEVER, INCLUDING WITHOUT LIMITATION THE DESIGN OF THE PUMP.  ITS MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ITS CONFORMITY TO THE PROVISIONS AND SPECIFICATIONS OF ANY PURCHASE ORDER, ORDER OR OTHER DOCUMENT OR STATEMENT RELATING THERETO.  IN NO EVENT SHALL MARCH BE LIABLE FOR LIQUIDATED, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING STRICT LIABILITY IN TORT, LOSS OF PRODUCTION OR DELAYS IN CONSTRUCTION).   

Chemical Disclaimer


The user must exercise primary responsibility in selecting the product's materials of construction, which are compatible with the liquid/s that come in contact with the product.  The user may consult March Manufacturing or a distributor to seek a recommendation of the product's materials of construction that the offers the optimum available chemical compatibility.  However neither March or the distributor shall be liable for product damage or failure, injuries, or any other damage or loss arising out of a reaction, interaction or any chemical effect that occurs between the materials of the product's construction and the liquids that come into contact the product.                                                                                     

 

   